Please note the Matrix-T is for CORNER fix only.
In general shower panels must be used in conjunction with pumped or pressurised water systems, (see Shower Pumps, Twin Impeller Shower Pump Installation) but can be used with many types of combination boiler (please check manufacturer’s performance data first).
Minimum pressure required is 0.7 bar when only one function can be used at a time
Pressure Requirements:
Minimum: 0.7 bar (running pressure)
Maximum: 10.00 bar
Optimum operation inlet pressure: 3.0 bar
Please Note: A separate hot and cold water supply, gravity fed by a storage tank of at least 112 litres (25 gallons) capacity is required.
| Flow rate in litres per minute using handset supplied with product. |  |
| Bar Pressure | Outlet Temperature | Handset Litres: per Minute | Body Jets Litres per minute | Handset & Bodyjet Combined |
| 1 bar (pumped) | 38 °C | 9.84 | 10 | 13 |
| 3 bar (pumped) | 38 °C | 14 | 15.5 | 21 |
| 5 bar (pumped) | 38 °C | 20 | 18 | 22 |
| 0.1 bar (gravity only) | 38 °C | 5.14 | 6.42 | 6.85 |
| |