In general shower panels must be used in conjunction with pumped or pressurised water systems, (see Shower Pumps, Twin Impeller Shower Pump Installation) but can be used with many types of combination boiler (please check manufacturer’s performance data first).

Minimum pressure required is 0.7 bar when only one function can be used at a time

Pressure Requirements:
Minimum: 0.7 bar (running pressure)
Maximum: 10.00 bar
Optimum operation inlet pressure: 3.0 bar

Please Note: The Powerpanel-T is an exception, which must not be connected to a remote shower pump or pumped system, as
the product has an integral pump within the unit. A separate hot and cold water supply, gravity fed by a storage tank of at least
112 litres (25 gallons) capacity is required.

Do not use the Powerpanel-T with a combination boiler or combination cylinder.